Sign In | Join Free | My chinacsw.com |
|
Warranty : 1years
Place of Origin : Zhejiang, China
Brand Name : TTN / OEM
Model Number : TTN-ECO PLUS 30-300kVA
Phase : Three Phase
Protection : Other
Weight : 300kg
Type : On-line
Application : All
Product name : 30KVA 60KVA 90KVA 120KVA 150KVA 180KVA modular ups with 30kw modules
Capacity : 180KVA/180KW
Input voltage : 138-485vac
Output : 380VAC/400VAC/415VAC
Certification : ISO9001/ISO14001/CE/ROHS
Power factor : 1.0
Wave Form : Pure Sinewave
HS CODE : 8504402000
Battery Voltage : 480VDC(40PCS 12V Lead acid battery)
Packaging Details : 1pcs into master carton on pallet
Port : Shenzhen/Ningbo/Shanghai/Guangzhou
Supply Ability : 5000 Piece/Pieces per Month
Price : $13,800.00/pieces 1-9 pieces
Model | ECO PLUS 90-30 | ECO PLUS 150-30 | ECO PLUS 300-30 | ||||||
Capacity | UPS Cabinet | 30~90kVA | 30~150kVA | 30~300kVA | |||||
UPS Module | 30kVA | ||||||||
3 | 5 | 10 | |||||||
Input | Phase | 3 Phase 4 Wires and Ground | |||||||
Rated Voltage | 380/400/415Vac | ||||||||
Voltage Range | 138~485Vac | ||||||||
Frequency Range | 40Hz-70Hz | ||||||||
Power Factor | ≥0.99 | ||||||||
Current THDi | ≤3%(100% linear load) | ||||||||
Bypass Voltage Range | Max.voltage: 220V:+25 %( optional +10%, +15%, +20%); 230V:+20 %( optional +10%, +15%); 240V:+15 %( optional +10%);Min. voltage: -45% (optional -20%,-30%) | ||||||||
Frequency protection range: ±10% | |||||||||
Power Walking In | Yes | ||||||||
Bypass back irrigation | Bypass back irrigation | ||||||||
Generator access | Yes | ||||||||
Output | Phase | 3 Phase 4 Wires and Ground | |||||||
Rated Voltage | 380/400/415Vac | ||||||||
Power Factor | 1 | ||||||||
Voltage Regulation | ±1% | ||||||||
Frequency | Utility Mode | ±1%,±2%,±4%,±5%,±10% of the rated frequency(optional) | |||||||
Battery Mode | (50/60±0.1%)Hz | ||||||||
Crest Factor | 3:1 | ||||||||
THD | ≤2% with linear load, ≤5% with non linear load | ||||||||
Efficiency | 96% | ||||||||
Overload | ≤ 110%, to bypass after 60min; ≤ 125%,to bypass after 10min; ≤ 150%,to bypass after 1min | ||||||||
Battery | Voltage | ±180V/192V/±204V/±216V/±228V/±240/±252/±264/±276/±288/±300Vdc(30/32/34/36/38/40/42/44/46/48/50pcs optional) | |||||||
Charging Current | UPS Cabinet | 30A Max. | 50A Max. | 100A Max. | |||||
UPS Module | 10A Max. | ||||||||
Transfer Time | Utility to Battery : 0ms; Utility to bypass: 0ms | ||||||||
Protection | Alarm | overload, utility abnormal, UPS fault, battery low, etc | |||||||
Protection | short circuit, overload, over temperature, battery low, fan fault alarm | ||||||||
Communication Interface | RS232, RS485, Intelligent slot x 2, Dry Contact,SNMP | ||||||||
Environment | Operating Temperature | 0℃~40℃ | |||||||
Storage Temperature | -25℃~55℃ | ||||||||
Humidity | 0~95% non condensing | ||||||||
Altitude | < 1500m | ||||||||
Other | Unit Dimensions(D*W*H) | UPS Cabinet | 850x600x1350mm | 850x600x1350mm | 850x600x2000mm | ||||
UPS Module | 620x440x86mm | ||||||||
Weight (Kg) | UPS Cabinet | 160 | 170 | 275 | |||||
UPS Module | 21 | ||||||||
Standards | EN62040-1, EN62040-2 |
![]() |
TTN modular UPS 100kVA 500kva 1200kva with 3 phase online module 15kVA 25kva 50kVA 75kVA new data center infrastructure Images |